    For the tobacco industry, there is currently no detection device and method for detecting the heating temperature and temperature uniformity of heated cigarette smoking sets. In order to solve the temperature measurement needs of micro rod-shaped heating sheets in a narrow space, this article developed a cigarette heating rod thermometer, and designed a new structure suitable for temperature measurement of cigarette heating rods. In order to verify the accuracy and reliability of the measurement results of the cigarette heating rod thermometer, uncertainty analysis of the thermometer was performed. The analysis results are based on the "GB/T 13283-2008 Accuracy Level of Detection Instruments and Display Instruments for Industrial Process Measurement and Control" standard. The measurement range is 100 ℃~400 ℃, meeting the requirements of level 0.1. The final experiment verified that the heating temperature field of different cigarettes can be effectively measured.