    摘要:

    低温环境下,变电站巡检机器人电池存在开路电压迟滞环畸变,导致荷电状态估计值存在严重的低温漂移累积、运动能耗预测结果出现显著的非平稳偏差。故本研究提出一种融合低温放电建模、运动能耗预测与分层补偿的续航能力提升策略。首先,建立半经验电化学模型,采用扩展卡尔曼滤波在线估计电池荷电状态,抑制低温非线性极化引起的累积漂移;然后,结合实时荷电状态与路径规划信息,闭式输出剩余续航时间预测结果;最后,设计双层补偿架构,上层依据续航紧张因子动态重排序巡检任务点并调整充电触发阈值,下层基于端口受控哈密顿理论设计能量控制器,通过注入阻尼与能量成形优化关节力矩分配,实现续航补偿。实验表明,在-18~-8℃低温环境下,该策略能够单机完成全部8个巡检点位,荷电状态利用率达76.2%,较现有方法提升43.1%~70.5%,作业时间延长64.8%,且瞬时功率变异系数低至0.11,电流样本熵降至0.52,验证了该测量可以实现对低温恶劣工况下续航能力的精准预测与高效补偿。

    Abstract:

    In low-temperature environments, the battery of the substation inspection robot exhibits open circuit voltage hysteresis loop distortion, resulting in severe low-temperature drift accumulation in the estimated state of charge and significant non-stationary deviations in the predicted motion energy consumption results. Therefore, this study proposes a range enhancement strategy that integrates low-temperature discharge modeling, motion energy consumption prediction and layered compensation. Firstly, a semi empirical electrochemical model is established, and an extended Kalman filter is used to estimate the state of charge of the battery online, suppressing the cumulative drift caused by low-temperature nonlinear polarization; then, combining real-time state of charge and path planning information, output the remaining endurance time prediction result in a closed form; finally, a dual layer compensation architecture is designed. The upper layer dynamically reorders inspection task points based on the endurance tension factor and adjusts the charging trigger threshold, and the lower layer designs an energy controller based on the port controlled Hamiltonian theory, optimizing joint torque distribution through injection damping and energy shaping, experiments have shown that in low-temperature environments ranging from -18 to -8℃, this strategy can complete all 8 inspection points on a single machine, with a utilization rate of 76.2% for the state of charge, which is 43.1% to 70.5% higher than existing methods. The operation time is extended by 64.8%, and the instantaneous power variation coefficient is as low as 0.11. The current sample entropy is reduced to 0.52, verifying that this measurement can achieve accurate prediction and efficient compensation of endurance under harsh low-temperature conditions.

    参考文献
    相似文献
    引证文献
引用本文

李中原,张健,许敏虎,李璐,贾海峰.变电站巡检机器人续航能力预测及补偿策略[J].电子测量技术,2026,49(14):49-58