基于Transformer模型的连续无创血压预测方法
DOI:
作者:
作者单位:

1.广东工业大学信息工程学院 广州 510006; 2.中国科学院北京纳米能源与系统研究所 北京 101400; 3.广州中医药大学基础医学院 广州 510006

作者简介:

通讯作者:

中图分类号:

TN911.7

基金项目:

广东省教育厅自然科学基金(2019KZDZX1040)项目资助


Continuous non-invasive blood pressure prediction method based on Transformer
Author:
Affiliation:

1.College of Information Engineering, Guangdong University of Technology,Guangzhou 510006, China; 2.Institute of Nanoenergy and Nanosystem, Chinese Academy of Sciences,Beijing 101400, China; 3.College of Basic Medicine, Guangzhou University of Chinese Medicine,Guangzhou 510006, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    动脉血压(ABP)波形包含丰富的心血管信息,有助于心血管疾病的预防和诊断。目前大部分基于光电容积脉搏波描记法(PPG)的血压预测方法仅预测收缩压(SBP)和舒张压(DBP),本文提出了一种由PPG信号预测ABP波形的血压测量方法。首先使用PPG信号作为输入,通过线性映射到高维空间,然后利用Transformer编码器结构进行特征提取,最后由线性层输出预测的ABP波形,由预测的ABP波形可计算出SBP和DBP等血压参数。实验结果显示,Transformer网络在MIMIC数据集中预测的ABP波形与实际波形的拟合效果良好,计算得到的SBP和DBP预测误差分别为(3.76±5.66) mmHg、(2.20±3.77) mmHg,且该方法符合美国医疗仪器促进协会(AAMI)的标准,同时在英国高血压协会(BHS)标准中达到 A 级。

    Abstract:

    Rich cardiovascular information is encompassed within the arterial blood pressure (ABP) waveform, offering valuable insights for the prevention and diagnosis of cardiovascular diseases. Despite the availability of several photoplethysmography (PPG)-based blood pressure prediction methods, they primarily focus on predicting systolic blood pressure (SBP) and diastolic blood pressure (DBP). This paper proposes a novel method for blood pressure measurement that predicts the entire ABP waveform from PPG signals. The proposed approach involves linearly mapping the PPG signal to a high-dimensional space and feature extraction using a Transformer encoder structure. A linear layer is then utilized to output the predicted ABP waveform, enabling the calculation of SBP and DBP. Experimental results demonstrate that the Transformer network provides an accurate fit to the actual ABP waveform in the MIMIC dataset, with predicted SBP and DBP errors averaging (3.76±5.66) mmHg and (2.20±3.77) mmHg, respectively. Additionally, the proposed method complies with the standards of the Association for the Advancement of Medical Instrumentation (AAMI) and achieves Grade A according to the British Hypertension Society (BHS) criteria.

    参考文献
    相似文献
    引证文献
引用本文

田俊豪,刘立程,王小林,刘梅.基于Transformer模型的连续无创血压预测方法[J].电子测量技术,2024,47(3):102-108

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2024-04-30
  • 出版日期: